Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

Code Block
languagebash
# mkdir -p /opt/akraino/tools 
# curl -L "https://nexus.akraino.org/service/local/artifactrepositories/snapshots/maven/redirect?r=snapshots&g=org.akraino.redfish&a=redfish&v=content/org/akraino/redfish/redfish/1.0.0-SNAPSHOT&e=/redfish-1.0.0-20180805.222845-10.tgz" | tar -xozv -C /opt/akraino/tools

...

Code Block
languagebash
# mkdir -p /opt/akraino/region
# curl -L "https://nexus.akraino.org/service/local/repositories/artifactsnapshots/content/maven/redirect?r=snapshots&g=org.akraino.org/akraino/regional_controller&a=/regional_controller&v=/1.0.0-SNAPSHOT&e=/regional_controller-1.0.0-20180807.212444-5.tgz" | tar -xozv -C /opt/akraino/region

...

  • SRV_NAME is the Bare Metal Server name
  • SRV_OOB_IP is the Bare Metal Server iDRAC IP
  • SRV_IP is the Bare Metal Server IP
  • Passwords are chosen for SRV_OOB_PWD and SRV_PWD
  • All remaining SRV_ prefixed options are adjusted as deemed appropriate
  • Remove all references to BUILD_WEBIP and BUILD_WEBPORT 

Code Block
languagebash
# host name for server
SRV_NAME=aknode42

# server oem - Dell or HPE (case sensitive)
SRV_OEM=Dell

# out of band interface information for server (idrac/ilo/etc)
SRV_OOB_IP=192.168.41.42
SRV_OOB_USR=root
SRV_OOB_PWD=ROOT_PASSWORD

# mac address of server to be used during the build - not required for Dell servers
# SRV_MAC=3c:fd:fe:b8:10:60

# name of network interface used during build when ipxe.efi is booted and when os is booted
# ipxe numbers ports from 0-n in pci bus order.
# the netx value will depend on how many nics are in the server
# and which pci device number is assigned to the slot
SRV_IPXE_INF=net4

# the build interface is the nic used by the Ubuntu installed to load the OS
SRV_BLD_INF=enp94s0f0

# the boot device is the device name on which the OS will be loaded
SRV_BOOT_DEVICE=sdg

# ipxe script to use - based on the os version and kernel to install
# valid options are script-hwe-16.04.5-amd64.ipxe or script-16.04.5-amd64.ipxe
SRV_BLD_SCRIPT=script-hwe-16.04.5-amd64.ipxe

# template xml file to set bios and raid configuration settings
SRV_BIOS_TEMPLATE=dell_r740_g14_uefi_base.xml.template
SRV_BOOT_TEMPLATE=dell_r740_g14_uefi_httpboot.xml.template
SRV_HTTP_BOOT_DEV=NIC.Slot.3-1-1

# VLAN to use during build and for final network configuration
SRV_VLAN=41

# basic network information for dhcp config and final server network settings
SRV_MTU=9000
SRV_IP=192.168.2.42
SRV_SUBNET=192.168.2.0
SRV_NETMASK=255.255.255.0
SRV_GATEWAY=192.168.2.200
SRV_DNS=192.168.2.85
SRV_DOMAIN=lab.akraino.org
SRV_DNSSEARCH=lab.akraino.org
SRV_NTP=ntp.ubuntu.org

# root password for server being built
SRV_PWD=SERVER_PASSWORD

# network bond information
SRV_BOND=bond0
SRV_SLAVE1=enp94s0f0
SRV_SLAVE2=enp94s0f1

...

The Regional Controller Node installation is now complete.

Akraino Portal Operations

Login

Visit the portal URL http://REGIONAL_NODE_IP:8080/AECPortalMgmt/ where REGIONAL_NODE_IP is the Portal IP.

Use the following credentials:

  • Username: akadmin
  • Password: akraino

Upon successful login, the Akraino Portal home page will appear.