Pre-Installation Requirements
Minimum Hardware Requirements
Qty. | Item | Comments |
---|---|---|
2 | x86 servers running CentOS 7.5 | - |
1 | ConnectX-5 NIC (FW: 16.24.0328 and up) | - |
1 | BlueField 25GbE SmartNIC with Arm processor (FW: 18.24.1000 and up) | - |
1 | 25GB/s SFP28 networking cable | - |
1 | QSA28 Adapter (100GB-to-25GB Adapter) | - |
1 | UART-to-USB cable | For SmartNIC USB console access |
1 | Mini USB Type B cable | For SmartNIC USB Console Access |
1 | bfb image to be loaded on the BlueField SmartNIC Arm. | Image contains:
|
- Insert ConnectX-5 NIC into Server A
- Insert BlueField SmartNIC into Server B
- Connect the SmartNIC UART cable from SmartNIC to its hosting Server B USB port #1
- Connect Mini USB cable from SmartNIC to its hosting Server B USB port #2
- Insert QSA28 Adapter into Server B 100GB port
- Connect one of the SmartNIC ports to the ConnectX-5 using 25GB cable
- Connect both servers to a management LAN
Recommended Hardware Requirements
...
N/A
Schema scripts
...
N/A
Jump Host Requirements
...
N/A
Network Requirements
...
N/A
Bare Metal Node Requirements
...
N/A
Execution Requirements (Bare Metal Only)NA
Hardware RequirementsNA
Software Prerequisites
- MLNX_OFED
Note
- Use automatic FM update during MLNX_OFED installation ONLY if the current BlueField FW version is 18.24.1000 (GA) or above. In case its older, manually burn the FW after MLNX_OFED installation.
- In case you plan to run DPDK on the host itself, install MLNX_OFED with "--dpdk --upstream-libs" flags
- The "bluefield" flag is not required in some of the MLNX_OFED versions and OS releases
Database PrerequisitesNA
Other Installation RequirementsNA
Installation High-Level Overview
SmartNIC Server Preparations
Install useful packages:
yum install -y screen minicom net-tools tcpdump usbutils net-utils sshpass iptables-services fio epel-release iperf wget git unzip perl pciutils lsof tcl libxml2-python tk unbound gtk2 atk cairo gcc-gfortran tcsh nvme-cli
Install MLNX_OFED with the mentioned flags below.
tar -xzvf MLNX_OFED_LINUX-4.4-2.5.11.0-rhel7.5-x86_64.tgz
cd MLNX_OFED_LINUX-4.4-2.5.11.0-rhel7.5-x86_64
./mlnxofedinstall --with-nvmf --bluefield --without-fw-update
Note
- Use automatic FM update during MLNX_OFED installation ONLY if the current BlueField FW version is 18.24.1000 (GA) or above. In case its older, manually burn the FW after MLNX_OFED installation.
- In case you plan to run DPDK on the host itself, install MLNX_OFED with "--dpdk --upstream-libs" flags
- The "bluefield" flag is not required in some of the MLNX_OFED versions and OS releases
Enable SR-IOV on FW (Optional):
mlxconfig -y -d /dev/mst/mt41682_pciconf0 s SRIOV_EN=1
mlxconfig -y -d /dev/mst/mt41682_pciconf0 s NUM_OF_VFS=8
Uncomment the following line in /etc/modprobe.d/rshim.conf to set the default RShim access method to the SmartNIC:
options rshim backend_driver=rshim_usb
Note
- When this line is commented, the first available driver will be used.
- When the mini USB cable is not used, the driver should be rshim_pcie
Create a file named ifcfg-tmfifo_net0 under /etc/sysconfig/network-scripts/ directory, with the following content:
NAME="tmfifo_net0"
HWADDR="00:1a:ca:ff:ff:02"
ONBOOT=yes
NETBOOT=yes
IPV6INIT=yes
BOOTPROTO=static
TYPE=Ethernet
IPADDR=192.168.100.1
NETMASK=255.255.255.0
ifcfg-tmfifo_net0 is the network interface used for IP communication between the x86 host and the SmartNIC with rshim_net driver.
Enable ip forwarding and set a NAT rule to allow the SmartNIC OS to communicate with the outer world via the host management interface:
sysctl -w net.ipv4.ip_forward=1
systemctl enable iptables
systemctl start iptables
iptables -F
iptables -t nat -A POSTROUTING -o <host_mgmt_interfac> -j MASQUERADE
service iptables save
Disable Firewall and Network Manager services
systemctl disable firewalld.service
systemctl disable NetworkManager
- Reboot the server. Once server is up again, run some configuration sanity tests:
To verify BlueField FW version:
mlxfwmanager --query
To verify RShim modules are loaded:
lsmod | grep -i rshim
To identify the backend active RShim driver:
cat /dev/rshim0/misc
To verify the NAT rule for SmartNIC communication with the outer world:
iptables -L -n -t nat
Download the BlueField Quick Start bfb image: https://mellanox.box.com/s/q44f501xq1e29yb1bjpsb9vzgqs89a76
Place the bfb image on the host and load it on the BlueField SmartNIC using the following command:
|
Use one of the console access methods described in the "SmartNIC Management Methods" section below to follow the image installation process.
...
Console over USB-Serial / Serial Port properties: Rate 115200, HW Flow Control OFF.
|
Console over USB (rshim_usb) / Serial Port properties: Rate 115200, HW Flow Control OFF
minicom -D /dev/rshim0/console |
SSH (rshim_net)
|
Note
SmartNIC OS is configured to obtain internet access via its hosting server.
...
Issue the following command on the server:
|
Follow the boot process using console access:
|
Note
This is not a power cycle of the SmartNIC.
...
Issue the following command on the server:
|
Follow the installation and boot process using the console access:
|
- SmartNIC Modes
BlueField SmartNIC can operate in two modes:
...
In order to identify the SmartNIC current mode, issue the following commands on the x86 hosting server:
|
Switching to EMBEDDED Mode from SEPERATED_HOST Mode
On the x86 host:
Enable EMBEDDED mode:
|
Reboot.
Verify:
|
On the Arm:
Issue the following commands to enable ECPF parameters (applied per port):
Note
The ECPF parameters will be available for setting only after completing the previous steps.
|
Reboot the x86 host.
Verify configuration:
Once the procedure is completed, issue the following command on both the x86 host and the Arm:
|
On x86 host: the output should list two net devices.
|
On Arm: the output should list four representors:
|
Issue the following commands on the Arm to see the correlation between PCI device and its representors:
|
Note
The rep0-0 / rep1-0 are the representors facing the x86 host and the rep0-ffff / rep1-ffff are the representors facing the network.
...
Enable SEPERATED_HOST mode:
|
Reboot.
Verify:
|
Testing Traffic in EMBEDDED Mode using DPDK
...
DPDK application is used to forward the traffic and bypass Arm OS kernel. Follow the configuration steps below to test it.
On the Arm
Stop OVS:
|
Verify hugetlbfs is mounted:
|
if not, mount it:
|
Set Hugepages:
|
Verify hugepages were allocated (look for HugePages_Total and Free):
|
Identify the SmartNIC PCI device ID:
|
Start testPMD application while probing the representors (pci device is 03:00.0):
|
Set IPs on both x86 host and ConnectX-5 host and test connectivity with ping (it will be forwarded by the Arm DPDK)
On the ConnectX-5 external host start iperf server:
|
On the x86 host, start iperf client:
|
While the test is running, you can check traffic statistics on Arm testPMD:
|
Install Bare Metal Jump HostNA
Creating a Node Inventory FileNA
Creating the Settings FilesNA
RunningNA
Bare Metal Deployment GuideNA
Virtual Deployment Guide
Standard Deployment OverviewNA
Snapshot Deployment OverviewNA
Special Requirements for Virtual DeploymentsNA
Install Jump HostNA
Verifying the Setup - VMsNA
...