Attributes

Description

Informational

Type

Time Critical Edge Compute

Functionally safe capable for Industrial implementations, and enabled for Real-Time

Industry Sector

Industrial Edge with applicability to applications where time-sensitive compute and/or functional safety are required


Business driver

Industrial Edge is shifting dramatically with manufacturers, oil and gas, energy and other major industries transitioning to software defined infrastructure just as the telecommunications sector has been undergoing a similar transformation.  Akraino has the opportunity to play a critical role in hosting scalable, tuned software defined infrastructure for Industrial potentially ushering in this transformation and coalescing the ecosystem.


Business use cases

Use cases in Manufacturing, Smart Buildings, general IIOT.

  • Virtualized PLC
  • Computer vision inference
  • Machine, sensor data inference
  • Process or discrete manufacturing closed loop control
  • Ethernet TSN
  • Functional Safety capable use cases
  • Discrete manufacturing soft PLC
  • Onramp for 5G-URLLC


Business Cost - Initial Build Cost Target Objective

Example: Dell 3000 - ~$800 list

Example: Dell 5000 - ~$1300 list

Example: HPE EL300 - ~$2500 list


Business Cost – Target Operational Objective

TBD - could be highly variable based upon scale of facility.  From smaller manufacturers with one facility to large refining facilities with potentially thousands of deployed units.


Security need

Functional Safety (FuSa) core OS certification.

Security for Industrial is a key vector, which is why this stack is in essence functionally safe - by using open source leadership software such as Zephyr and ACRN - projects designed to meet both functional safety and real time requirements for security at the core of the stack.  By leveraging Kata Containers, all container workloads can leverage VT for containerized workload isolation.

Trusted Execution Environment compatible.


Regulations

IEC 61508 - Safety Integrity Level


Other restrictions

For industrial deployments:-

  • IEC-600068-2-27, IEC 600068-2-64

  • IP50 rated

  • Operational humidity: 8 to 90%, noncondensing

  • Tested in accordance with IEC-600068-2-56 Non-operating humidity: 5 to 95%, noncondensing

  • Tested in accordance with IEC-600068-2-56

  • MIL – 810G Tested

  • Storage temperature range: -40˚C to +70˚C

  • MIL-PRF-28800F class 3 limits

  • Operational, -30˚C to 70˚C (-22˚F to 158˚F)


Additional details

Differentiation:

Ruggedized implementation.  Supports functional safety workloads.

Potential to attract new members to Akraino project

○ Industrial ODM’s e.g. Advantech, Adlink

○ Industrial OEM’s/ISV’s e.g. TTTech, Nebbiolo, IOTech

○ Industrial end-users e.g. ExxonMobil

...