Compute K8s cluster will actually run the workloads and it installed on Baremetal nodes

Hardware Requirements

Minimum Hardware Requirement:

...

Jump server required to be installed with Ubuntu 18.04 server, and have 3 distinguished networks as shown in figure 1

Network Requirements

Bare Metal Node Requirements

Execution Requirements (Bare Metal Only)

Jump server Hardware Requirements

...

    Four or more hubs, with cabling, to connect four networks.


Hostname

CPU Model

Memory

Storage

1GbE: NIC#, VLAN,

(Connected

extreme 480 switch)

10GbE: NIC# VLAN, Network

(Connected with IZ1 switch)

Jump

Intel

2xE5-2699

64GB

3TB (Sata)
180 (SSD)

IF0: VLAN 110 (DMZ)
IF1: VLAN 111 (Admin)

IF2: VLAN 112 (Private)
VLAN 114 (Management)
IF3: VLAN 113 (Storage)
VLAN 1115 (Public)


Jump server Software Requirements:

    ICN R2 release support Ubuntu 18.04 - ICN BP install all required software during "make install"

Network Requirements

Please refer the figure 1, for all the network requirement in ICN BP

Please sure you have 3 distinguished networks net A, Net B and Net C as mentioned in figure 1. Local controller uses the Net B and Net C to provision the Baremetal servers to do the OS provisioning.

Bare Metal Node Requirements

Compute k8s cluster:

Compute server Hardware Requirements:

(Tested as below)


Hostname

CPU Model

Memory

Storage

1GbE: NIC#, VLAN,

(Connected

extreme 480 switch)

10GbE: NIC# VLAN, Network

(Connected with IZ1 switch)

node1

Intel

2xE5-2699

64GB

3TB (Sata)
180 (SSD)

IF0: VLAN 110 (DMZ)
IF1: VLAN 111 (Admin)

IF2: VLAN 112 (Private)
VLAN 114 (Management)
IF3: VLAN 113 (Storage)
VLAN 1115 (Public)

node2

Intel

2xE5-2699

64GB

3TB (Sata)
180 (SSD)

IF0:  VLAN 110 (DMZ)
IF1: VLAN 111 (Admin)

IF2: VLAN 112 (Private)
VLAN 114 (Management)
IF3: VLAN 113 (Storage)
VLAN 1115 (Public)

node3

Intel

2xE5-2699

64GB

3TB (Sata)
180 (SSD)

IF0: VLAN 110 (DMZ)
IF1: VLAN 111 (Admin)

IF2: VLAN 112 (Private)
VLAN 114 (Management)
IF3: VLAN 113 (Storage)
VLAN 1115 (Public)


Compute server Software Requirements:

The local controller will install all the software in compute servers right from OS, the software required to bring up the Kubernetes cluster

Network Prerequisites:

Execution Requirements (Bare Metal Only)

ICN BP check all the precondition and execution requirements for both Baremetal and VM deploymentPlease sure you have 3 distinguished networks net A, Net B and Net C as mentioned in figure 1. Local controller uses the Net B and Net C to provision the Baremetal servers to do the OS provisioning.

Installation Overview

Installation is two-step process and everything starts with one command "make install"

...