You are viewing an old version of this page. View the current version.

Compare with Current View Page History

« Previous Version 3 Next »

Overview

The ThunderX2 Pod consists of 6 Arm®v8 based Gigabyte R281-T91 servers with the following specifications per server:

  • CPU:
    • 2x 28 core 2.0 GHz Marvell TX2 Processors
  • RAM:
    • 4x 32GB RDIMM-Tx2 
  • Storage:
    • 1x 480GB SSD
    • 1x 1TB HDD
  • Networking:
    • 2x 10Gbe SFP+ (not connected)
    • 2x 1/10Gbe BASE-T (1 connected)
    • 2x 40Gbe QSFP (coming soon)
    • 1x IPMI / Lights-out Management

Usage & Users

Blueprint(s) / Description(s): 

Primary Contact: 

Secondary Contact: 

Networking

The networking within the pod is currently provided by a 10Gbe BASE-T switch, which only supports static configurations (i.e. no SDN control).  This switch will be replaced with an Edgecore 7816-64X that is currently on order, along with 40Gbe NICs to be installed on each server.

NetworkIP NetworkVLAN IDDescription
IPMI / Management

10.11.3.0/24

GW: 10.11.3.1

3003Connections to all IPMI interfaces on each server and the switch management.interface
Public

10.11.4.0/24

GW: 10.11.4.1

3004Public network (able to reach the Internet), available to each server.

Servers

Server NameIPMI AddressIPMI VLAN IDPublic Network AddressPublic Network VLAN IDSwitch Port(s)
gigabyte110.11.3.11300310.11.4.113004TBD
gigabyte210.11.3.12300310.11.4.123004TBD
gigabyte310.11.3.13300310.11.4.133004TBD
gigabyte410.11.3.14300310.11.4.143004TBD
gigabyte510.11.3.15300310.11.4.153004TBD
gigabyte610.11.3.16300310.11.4.163004TBD

Notes:

  1. Public Network is un-tagged on switch ports facing the servers.
  2. Switch port numbers will be assigned when the Edgecore switch is installed with 40Gbe connections to each server.


  • No labels